Frequency Range (-10 dB) |
70 Hz - 23 kHz |
Midrange (±1.5 dB, typical) |
130 Hz - 14 kHz |
100 Hr Power Capacity |
200 Watts Continuous Program Power ; 100 Watts Continuous Pink Noise |
Nominal Coverage |
100° x 100° |
Nominal Sensitivity |
87 dB SPL, 1W @ 1 m (3.3ft) |
Maximum SPL @ 1m |
113 dB continuous peak pink noise ; 107 dB continuous average pink noise ; 103 dB continuous average music or speech |
Directivity Factor (Q) |
4.9, averaged 500 Hz to 4 kHz |
Directivity Index (DI) |
6.9 dB, averaged 500 Hz to 4 kHz |
Nominal Impedance |
8 ohms |
Minimum Impedance |
6.7 ohms at 230 Hz |
Crossover Type |
Second Order Lowpass, Second Order Highpass, Complex Optimization for Maximally Flat Response |
Transformer Taps |
170V = 60W, 30W, 15W, 7.5W taps (Taps #4,#3, #2 & #1) ; 100V = 60W, 30W, 15W taps (Taps #3, #2, & #1) ; Thru position = 8 ohms nominal |
Low Frequency Transducer |
130 mm (5.25 in) polypropylene-coated paper with WeatherEdge surround, 25 mm (1 in) voicecoil on kapton former |
High Frequency Transducer |
20 mm (.75 in) titanium coated PEI |
Included Accessories |
1 Pr MTC-PC input panel cover, InvisiBall mounting base, 6 mm x 100 mm InvisiBall hex wrench |
Optional Accessories |
MTC-25V for vertical columnar mounting of up to 3 speakers ; MTC-25/23H for horizontal splaying of 2 speakers. Three brackets array either 3 or 6 speakers in a hanging array module for 360° horizontal coverage. ; MTC-28/25CM to install speaker down from the ceiling. Check JBL Control Contractor Bracket and Adapter Handbook. ; MTC-xxWMG WeatherMax™ Stainless Steel Grille with a three-layer backing, including vapor barrier to break up driving precipitation. Available in black or white (-WH). |
Dimensions (H x W x D) |
236 x 186 x 159 mm (9.3 x 7.4 x 6.3 in) |
Net Weight (ea) |
4.0 kg (9 lbs) |
Shipping Weight (pair) |
9.0 kg (20 lbs) per pair |
Enclosure Material |
High Impact polystyrene |
Grille |
Painted stainless steel, black or white to match cabinet, paintable |
Overload Protection |
Full-range power limiting to protect network and transducers. Internal fuse to protect during exceptional overload condition |
Environmental |
Exceeds Mil Spec 810 for humidity, salt spray, temperature & UV. IEC 529 IP-X4 splashproof rating |
Termination |
Screw-down terminal strip, zinc-plated copper base, nickel plated metal screws/washers, accepts up to 9 mm outside 4 mm inside open lug (#6, #8 or #10), plus bare wire. (up to 12 AWG) |
Safety Agency Rating |
Transformer is listed per UL1876 |
Rotation |
Against wall on InvisiBall Base |